HOME PAGE

Vent Silencers

Steam exhausts
Air vents
Process Gases
Relief valves
Safety valves
Bypass valves
Blow down vents
High temp vents
Incinerators

Diffuser Silencers

Atmospheric vents
Control valves
Pressure let down
Steam Vents & Process Vents
Pressure regulators

In-Line Silencers

Control valves
Regulators
Orifice plates
Gas ejectors
Steam ejectors
Gas compressors
Axial compressors
Centifugal compressors
Roots blowers and
exhausters
Multi-lobe blowers and exhausters

Surge Tanks


Drinking Water
Raw water
Foul Water
Sewerage
Hydro-carbons

Ancillary Surge Controls & Equipment

Air Compressors
Electrical Controls Control Panels
Level Controls

Flo-Dyne Installation & Commissioning Services

Pipeline Surge Analysis & Reporting

Refurbishment and repair

Surge Vessels
Compressor systems
Control panels

Pulsation Dampeners

Roots Blowers
Exhausters
Multi-Lobe Blowers
Recip compressor
Recip pumps Suction Lines
Discharge Lines

Acoustic Filters

Hydraulic pumps
Refrigerant Compressors
Air Conditioning Compressors


General Information


Quality Registration to
ISO9001

Surge Tanks

 

Vent Silencers

 

Pulsation Dampeners

 

In-line Silencers

Blower Silencers

Bulletins

 

 

BLOWER SILENCERS

Lobe type and multi-vane compressors generate high-energy noise levels at the fundamental and initial harmonic frequencies. With no absorptive pack, rugged construction and high quality materials, this multi-chamber design is tuned to handle these frequencies and is very effective in reducing tonal radiation from the pipe work connected to these machines.

blower silencerUsing powerful computer design programs
Flo-Dyne are able to predict and analyse the
performance of each silencer application.

Flo-Dyne engineers are able to adjust internal dimensions and observe the effects on performance, to ensure optimum performance is achieved to adjust internal dimensions and observe the effects on performance. Pressure vessel fabrication techniques are used with pressure ratings given. Carbon steel construction is standard, but other materials are available for special applications.

The graph shown below shows actual measured dampener performance that equates to over 30 dB reduction in pulsation level at the fundamental pulsation frequency and the first harmonic at a flow rate of 29000CFM @ 68°F from a rotary blower.

                            blower performance graph


Contact us now with your requirements.

UK office:
Tel: +44 (0) 1494 770088
Fax: +44 (0) 1494 770099
Email: sales@flo-dyne.net


India office:
Tel: +91 77 384 97 300
Email: sales-india@flo-dyne.net